SoftTree Technologies
Technical Support Forums
|
|
Author |
Message |
kyofm
Joined: 30 Sep 2014 Posts: 21
|
|
24x7 and WinBatch Error 193 |
|
I am trying to run a WinBatch script inside 24x7 Scheduler v 5.2 Build 417 on Windows 7 and am getting the following error in the log:
Create process error. Extended error: Cannot run program "L:\Library\BatchJobs\make-all-files.wbt":
CreateProcess error=192, %1 is not a valid Win32 application.
I have successfully run the WinBatch script outside of 24x7 on the same machine. Also the same script ran fine in 24x7 v 3.4.25e on Windows XP.
Is WinBatch still supported in v.5? What am I missing?
Thanks in advance.
|
|
Tue Sep 30, 2014 11:21 am |
|
 |
SysOp
Site Admin
Joined: 26 Nov 2006 Posts: 7948
|
|
|
|
Try using full command line referencing winbatch executable file and passing script name as a parameter
|
|
Tue Sep 30, 2014 1:09 pm |
|
 |
kyofm
Joined: 30 Sep 2014 Posts: 21
|
|
|
|
I think I am running into issues not specifically related to WinBatch now.
While testing I re-wrote the script in VBScript using the built-in editor in 24x7 and received two errors in the log after running the job. If I run the script outside of 24x7 it works with no problems.
Error 1. An error occurred while executing automation script: Error #0: Unknown error
Error 2. Job completed with exit code 1. This exit code does not satisfy job exit code condition. Job failed.
This is the VBScript I am trying to run:
Dim accessObject
Set accessObject = createObject("Access.Application")
accessObject.openCurrentDatabase("L:\Library\AccessDatabases\Overnight.accdb")
accessObject.DoCmd.RunMacro "starter"
'Scheduler generates L:\Library\batchjobs\completed\onite.txt when done processing
accessObject.Quit
I have also tried to run a simple message box in VBScript embedded in 24x7 (Code: MsgBox "Hello") and if I try to validate the code inside 24x7's editor I get an error that says "Line 0 not null".
Is something not set up correctly in 24x7 install or on the machine?
|
|
Tue Oct 07, 2014 7:36 am |
|
 |
kyofm
Joined: 30 Sep 2014 Posts: 21
|
|
|
Tue Oct 07, 2014 9:03 am |
|
 |
SysOp
Site Admin
Joined: 26 Nov 2006 Posts: 7948
|
|
|
|
Thank you for the status update.
The embedded job script should have
 |
 |
Sub Main
...
End sub |
The scheduler is looking for sub Main as an entry point when running and when debugging scripts.
|
|
Tue Oct 07, 2014 9:23 am |
|
 |
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
|
|